ARM2 Analog Current or Voltage to Dual 4-20mA Outputs Module
$98.50$197.00
available: In Stock
BULK ORDERS AND LESS COMMON PRODUCTS MAY REQUIRE ADDITONAL TIME FOR SHIPMENT.CONTACT USVIA PHONE OREMAILTO REQUEST MORE INFORMATION ON AVAILABILITY, AND FOR PART NUMBERS NOT LISTED MORE OPTIONS AVAILABLE. PLEASE CALL OR EMAIL US FOR FURTHER INFORMATION The
BULK ORDERS AND LESS COMMON PRODUCTS MAY REQUIRE ADDITONAL TIME FOR SHIPMENT.CONTACT USVIA PHONE OREMAILTO REQUEST MORE INFORMATION ON AVAILABILITY, AND FOR PART NUMBERS NOT LISTED
MORE OPTIONS AVAILABLE. PLEASE CALL OR EMAIL US FOR FURTHER INFORMATION
The ARM2 will accept a single analog (voltage or current) signal and split that signal into two DC non-isolated current sourcing outputs that can be re-scaled. Its primary application is as a signal splitter. The outputs are always scaled identically and will always track each other. The top-adjust trimmer potentiometers can be used to make ne adjustments to output ranges for maximum exibility. This device can attenuate an input signal to 100%. The ARM2 also has an adjustable gain and oset. The output gain can be adjusted from 1 to 20 times the input (gain will vary depending on input). The ARM2 also has the ability to reverse an input signal. The ARM2 has a regulated 23 VDC power supply output to power sensors. The ARM2 can also accept a resistance input by using voltage divider applications. The ARM2 is eld calibratable, however, factory calibration is available upon request for an additional charge. This will speed up installation time for the end user.
Applications:
Signal Loop Monitoring
Resistance to Current Conversion
Voltage to Current Conversion
Current to Current Conversion
Shrink or Expand Sensor Ranges
Increase Analog Input Resolution
Reverse a Signal
Adapt Non-compatible Signals
Specifications:
Supply Voltage: 22.8 to 30 VDC, 21.6 to 26.4 VAC
Supply Current: 100 mA maximum
Input Voltage Signal Range (@ Impedance):0-35 VDC @ 1,000,000
Input Current Signal Range (@ Impedance):0 to 44 mA @ 250
Input Resistance Signal Range:0 to 500,000
Field Adjustable Ranges:Multi-turn potentiometers
Output Current Signal Range: Signal Gain 1 to 20 times (nominal) depending on input value
Signal Output Accuracy: Less than or equal to 1% of output span over full temperature range when using 1:1 input to output | Accuracy is calibration dependent over full temperature range
Output Signal Attenuation:0 to 100%
Output Signal Offset:0.25 to 20 VDC
Output Signal Inversion (RA): 20 to 0 mA (nominal)
Output Current Load Impedance:750 @ 20 mA
Regulated Power Output: 23 VDC nominal @ 24 VAC Power Supply, 30 mA maximum
Reviews